Prix

Commencez à sauver des vies en améliorant le retraitement de vos dispositifs médicaux.

Chapitres du Cours

  • 2

    Mythe Numéro 1

    • Mythe # 1 – Tout ce qui passe à l’autoclave est stérile.

    • Joint de Porte Endommagé

    • Questionnaire # 1

  • 3

    Mythe Numéro 2

    • La chaleur tue tout ce qui est dans l’ autoclave.

    • La relation direct entre la temperature et la pression.

    • Questionnaire # 2

  • 4

    Mythe Numéro 3

    • Je viens de recevoir mon nouvel autoclave directement du fabricant et je n’ai qu’à le brancher et m’en servir!

    • Questionnaire # 3

  • 5

    Mythe Numéro 4

    • Le processus de stérilisation n’échoue jamais.

    • Questionnaire # 4

  • 6

    Mythe Numéro 5

    • Laisser tremper les instruments dans une solution chimique ou enzymatique est une méthode de nettoyage adéquate

    • Questionnaire # 5

  • 7

    Mythe Numéro 6

    • Je n’ai pas besoin de tester mon nettoyeur ultrasonique.

    • Questionnaire # 6

  • 8

    Mythe Numéro 7

    • Tous les emballages stérilisés cessent d’être stériles après une période donnée

    • Questionnaire # 7

  • 9

    Mythe Numéro 8

    • Nous n’avons pas besoin d’indicateurs chimiques supplémentaires dans les sachets, car il y en a déjà une qui est intégrée au sachet.

    • Questionnaire # 8

  • 10

    Mythe Numéro 9

    • Je peux empiler les sachets les uns sur les autres dans l’autoclave.

    • Questionnaire # 9

  • 11

    Mythe Numéro 10

    • Je peux manipuler des sachets et les emballages même s’ils sont encore chauds.

    • Questionnaire # 10

  • 12

    Mythe Numéro 11

    • Je peux plier les sachets auto-scellants pour en placer plus dans la chambre intérieure.

    • Questionnaire # 11

  • 13

    Mythe Numéro 12

    • Nous pouvons mettre plusieurs instruments dans les sachets auto-scellants pour la stérilisation.

    • Questionnaire # 12

  • 14

    Mythe Numéro 13

    • Je peux doubler le sachet auto-scellant pour stériliser un dispositif.

    • Questionnaire # 13

  • 15

    Mythe Numéro 14

    • Je peux placer des instruments dans un sachet scellé et de placer le sachet dans un contenant avant le passage à l’autoclave.

    • Questionnaire # 14

  • 16

    Mythe Numéro 15

    • Je peux écrire sur le matériel d’emballage jetable ou sur la surface poreuse d’un sachet auto-scellant.

    • Questionnaire # 15

  • 17

    Mythe Numéro 16

    • Les implants ou les explants orthopédiques exigent le même contrôle de la qualité que les instruments chirurgicaux.

    • Questionnaire # 16

  • 18

    Mythe Numéro 17

    • J’ai échappé un article sur le sol, est-ce que je peux faire une stérilisation ultra-rapide (« flash ») et le reprendre le plus rapidement possible?

    • Questionnaire # 17

  • 19

    Mythe Numéro 18

    • Un nouvel instrument ou un implant non stérile à l’achat peut être passé à l’autoclave directement.

    • Questionnaire # 18

  • 20

    Mythe Numéro 19

    • Le ruban adhésif d’identification peut servir d’étiquettre en toute sécurité.

    • Questionnaire # 19

  • 21

    Mythe Numéro 20

    • Ce n’est pas grave s’il y a de la rouille sur les instruments.

    • Questionnaire # 20

  • 22

    Mythe Numéro 21

    • Tous les instruments peuvent subir le même cycle à l’autoclave.

    • Questionnaire # 21

  • 23

    Mythe Numéro 22

    • Tous les articles à usage unique peuvent être restérilisés et réutilisés.

    • Questionnaire # 22

  • 24

    Mythe Numéro 23

    • Les sondes endotrachéales ont seulement besoin d’être bien rincées ou nettoyées avec de l’eau et du savon entre les patients.

    • Questionnaire # 23

  • 25

    Mythe Numéro 24

    • J’ai ouvert un emballage en salle de chirurgie et le n’ai pas utilisé tous les instruments. Je peux donc mettre les instruments propres directement dans le stérilisateur.

    • Questionnaire # 24

  • 26

    Mythe Numéro 25

    • Les pièces à main dentaires ne peuvent pas être stérilisées à la vapeur.

    • Questionnaire # 25

  • 27

    Mythe Numéro 26

    • Il n’existe aucune ligne directrice relative au retraitement des dispositifs médicaux.

    • Questionnaire # 26

  • 28

    Evaluation

    • Merci de prendre le temps de compléter ce questionnaire - 5 minutes ou moins

    • Évaluation du cours

    • Avis

Témoignage - En anglais seulement.

Exemplary and Knowledgable Reprocessing Technician

Dr. P, BVSc (Hon), MVetSurg, MVetClinStud, DACVS-SA

As an ACVS-SA boarded surgeon who has worked with and known Daniel for four years, I can attest to Daniel’s expertise, professionalism and passion in his field. He is an exemplary and knowledgeable reprocessing technician, and I thoroughly endorse his desire to teach and impart his wisdom to like-minded professionals.

Desire to Teach Using Innovative Means to Simplify Concepts.

Dr. C DVM

For as long as I have known and worked with Daniel in all different capacities over the years, the one quality that has always stood out is his desire to teach and train in every facet that he works in. When he first became a full-time trainer, he excelled and developed an extensive campus-wide training program from the ground up, creating new material and using innovative means to deliver the didactic and practical courses to a wide audience. As a trainer, he is patient and approachable and possesses the ability to simplify concepts to his students. I would highly recommend Daniel as a trainer and any course that he has designed.

Experienced and Knowledgeable

Gayle, RVT, RLMAT

Daniel is an experienced and knowledgeable instructor, with years of expertise in both the animal and human health care systems. His materials are thorough and well planned, yet easy to follow, and his delivery demonstrates his passion for teaching others. Daniel’s diligence will ensure that learning materials are relevant, and broad in scope, to prepare technicians for their workplace.

Leader, Professional and Knowledgeable.

Dr. AG, BSc., DVM., DipMed., MSc.

I had the pleasure of working with Daniel as his manager over a four-year period of time. Daniel is the supreme professional as he is knowledgeable, capable, empowered and motivated to his profession. His passion for reprocessing, along with his inventive abilities and problem-solving abilities, have made him an invaluable team member and leader. Rarely does one find such talent and I am sure that anyone that embarks on this learning process with him will be not only be challenged but will also become a strong proponent for reprocessing

Knowledgeable and Passionate about Quality Control and Elevating Standards.

Dr. S, DVM, Diplomate ACVS-SA

Daniel's knowledge and expertise in his subject matter are incredibly vast, and he is the most knowledgeable person I have ever come across in all aspects of attaining and maintaining the physical qualities of a high quality operating theatre. He is passionate about the aspects of quality control that elevates the functioning of our hospital in a manner that is unsurpassed by any hospital I have ever experienced. His standards contribute greatly to the quality of our surgical service.

Detailed, Informative & Realistic

Ashley, LVT Regional Technician Director

This course has been extremely helpful in creating guidelines for my veterinary teams. After taking the course myself, I've identified multiple gaps in our current medical device reprocessing protocols. In veterinary medicine, our instrument care instruction is cursory and often incomplete. To live up to the oaths we take as veterinary professionals, we need to make serious efforts to do no harm to our patients. When we don't take instrument care seriously, we are putting the safety of our patients at risk and doing a disservice to our clients. Veterinary teams will find this course helpful in revisiting and revamping their current processes. Thanks, Daniel!

S'inscrire à ce cours maintenant!

Commencez à sauver des vies en améliorant vos standards de reprocédé des dispositifs médicaux.

Votre Instructeur

Bilingue Français/Anglais

Instructeur

Daniel JF Harvey

Daniel Harvey est technicien certifié en retraitement de dispositifs médicaux (MDRT), en plus d’être technicien en santé animale certifié (TSAc). Il est diplômé du programme de retraitement des dispositifs médicaux du Vancouver Community College depuis 2016, du programme de Technique de santé animale depuis 1997 et du programme de Soins infirmiers depuis 1988. Daniel a plus de 15 ans d’expérience de travail en installation animalière à titre de TSAc, comme coordonnateur de la formation et gestionnaire. Il a contribué à la mise en place et assure actuellement la gestion du département de retraitement de dispositifs médicaux dans un centre vétérinaire spécialisé. Il a travaillé comme technicien en retraitement de dispositifs médicaux à la Faculté de dentisterie et dans une clinique de fertilité.

Credit de Formation Continue.

Earn 4 CE Credits with BCVTA
Earn 1 CE Credit per hour with CDSBC
Earn 4 CE Credits with SAVT
Earn 4 CE Credits with OAVT
Earn 4 CE Credits with CALAS/ACSAL
NBVMA Earn 4 credits
Earn 4 CE Credits with ATSAQ

Obtenez vos Credit de Formation Continue.

Faites parvenir votre certificat certificat d’achèvement personnalisé à votre association professionelle afin d'obtenir vos credits de formation continue.